| Severity | Isolated | Pattern | Widespread |
|---|---|---|---|
| Immediate jeopardy | J· | K· | L· |
| Actual harm | G· | H· | I· |
| Potential harm | D6 | E12 | F12 |
| Minimal | A· | B· | C· |
CMS publishes about the three most recent standard surveys plus complaint and infection-control inspections from the prior three years. Older findings leave the dataset; their absence is not evidence they never happened.
Federal certification and the state license are different records. A nursing home is licensed by the state and, separately, certified by CMS to bill Medicare and/or Medicaid. We link them by the CCN when the state publishes it; otherwise by exact address, house number and street, or exact name within the same ZIP, and label that link as inferred. Never by name alone.
| Date | Domain | Survey types | Citations | Most severe | Open | |
|---|---|---|---|---|---|---|
| Aug 5, 2025 | Fire safety | Fire Safety Standard | 2 | Potential harm | — | Open → |
| Aug 5, 2025 | Health | Health Standard | 2 | Potential harm | — | Open → |
| Sep 4, 2024 | Fire safety | Fire Safety Standard | 15 | Potential harm | — | Open → |
| Sep 4, 2024 | Health | Health Complaint, Health Standard | 2 | Potential harm | — | Open → |
| Aug 25, 2023 | Fire safety | Fire Safety Standard | 6 | Potential harm | — | Open → |
| Aug 25, 2023 | Health | Health Standard | 3 | Potential harm | — | Open → |
| Severity | Isolated | Pattern | Widespread |
|---|---|---|---|
| Immediate jeopardy | J· | K· | L· |
| Actual harm | G· | H· | I· |
| Potential harm | D6 | E12 | F12 |
| Minimal | A· | B· | C· |
| Date | Tag | Deficiency | Scope / severity | Correction | Flags |
|---|---|---|---|---|---|
| Aug 5, 2025 | K-0521 | Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions. Services Deficiencies · Environment & life safety | E · Potential harm Pattern | No revisit needed | |
| Aug 5, 2025 | K-0921 | Ensure that testing and maintenance of electrical equipment is performed. Gas, Vacuum, and Electrical Systems Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Sep 22, 2025 | |
| Aug 5, 2025 | F-0684 |
“Corrected” does not erase a citation: the historical finding stays listed with its disposition. Narrative statements of deficiencies are not part of the CMS dataset; see Care Compare for the official inspection report.
CMS ratings apply to CMS-certified nursing homes only and are relative within each state. They are not a guarantee of any individual resident’s experience.
CMS reports the legal business name as not available.
Not part of a CMS-reported chain.
Coordinates as published by CMS.
| Facility | Distance | Beds | CMS overall | Last inspection | Citations (window) | Fines |
|---|---|---|---|---|---|---|
| Park View Care Center 328 West Vine Street, Edgerton, OH 43517 CCN 365570 | 10.6 km | 74 | Mar 5, 2026 | 32 | — | |
| Auburn Village 1751 Wesley Road, Auburn, IN 46706 CCN 155666 | 14.4 km | 111 | May 26, 2026 | 39 | — | |
| Betz Nursing Home 116 Betz Rd, Auburn, IN 46706 CCN 155694 | 15.2 km | 114 | Sep 15, 2025 | 10 | — |
| Source | Record | Facts | Evidence | Source release | Retrieved |
|---|---|---|---|---|---|
| CMS Provider Information US-CMS | 155386 | name, address, phone, certification, certified_beds, ownership_type, legal_business_name, chain | Verified | Oct 1, 2026 | Nov 7, 2026 |
| CMS Provider Information US-CMS | 155386 | ratings, staffing, health_survey_score Five-Star ratings and PBJ staffing apply to the CMS-certified universe only. | Verified | Oct 1, 2026 | Nov 7, 2026 |
| CMS Provider Information US-CMS | 155386 | county_fips County assigned by locating CMS coordinates in Census county boundaries (the CMS county name did not match the Census code list). | Inferred | Oct 1, 2026 | Nov 7, 2026 |
First seen by Carefield Nov 7, 2026 · last changed Nov 7, 2026. This record as JSON · Report a correction
| Provide appropriate treatment and care according to orders, resident’s preferences and goals. Quality of Life and Care Deficiencies · Clinical care |
| D · Potential harm Isolated |
| Corrected Aug 23, 2025 |
| Aug 5, 2025 | F-0812 | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. Nutrition and Dietary Deficiencies · Food, nutrition & hydration | F · Potential harm Widespread | Corrected Aug 23, 2025 |
| Sep 4, 2024 | K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. Egress Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0281 | Install proper backup exit lighting. Egress Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0291 | Install emergency lighting that can last at least 1 1/2 hours. Egress Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0300 | Meet other general requirements that are deficient. Egress Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0321 | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. Smoke Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0324 | Provide properly protected cooking facilities. Smoke Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0341 | Install a fire alarm system that can be heard throughout the facility. Smoke Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. Smoke Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0351 | Install an approved automatic sprinkler system. Smoke Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0353 | Inspect, test, and maintain automatic sprinkler systems. Smoke Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0363 | Install corridor and hallway doors that block smoke. Smoke Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0511 | Have properly installed electrical wiring and gas equipment. Services Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0521 | Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions. Services Deficiencies · Environment & life safety | F · Potential harm Widespread | Waiver granted Oct 9, 2024 |
| Sep 4, 2024 | K-0712 | Have simulated fire drills held at unexpected times. Miscellaneous Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | K-0918 | Have generator or other power source capable of supplying service within 10 seconds. Gas, Vacuum, and Electrical Systems Deficiencies · Environment & life safety | F · Potential harm Widespread | Corrected Oct 9, 2024 |
| Sep 4, 2024 | F-0684 | Provide appropriate treatment and care according to orders, resident’s preferences and goals. Quality of Life and Care Deficiencies · Clinical care | D · Potential harm Isolated | Corrected Sep 19, 2024 | Complaint |
| Sep 4, 2024 | F-0693 | Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube. Quality of Life and Care Deficiencies · Clinical care | D · Potential harm Isolated | Corrected Sep 19, 2024 |
| Aug 25, 2023 | K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. Egress Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Nov 13, 2023 |
| Aug 25, 2023 | K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. Egress Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Nov 13, 2023 |
| Aug 25, 2023 | K-0271 | Have exits that are accessible at all times. Egress Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Nov 13, 2023 |
| Aug 25, 2023 | K-0363 | Install corridor and hallway doors that block smoke. Smoke Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Nov 13, 2023 |
| Aug 25, 2023 | K-0521 | Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions. Services Deficiencies · Environment & life safety | F · Potential harm Widespread | Waiver granted Nov 13, 2023 |
| Aug 25, 2023 | K-0741 | Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed. Miscellaneous Deficiencies · Environment & life safety | E · Potential harm Pattern | Corrected Nov 13, 2023 |
| Aug 25, 2023 | F-0554 | Allow residents to self-administer drugs if determined clinically appropriate. Resident Rights Deficiencies · Resident rights & abuse/neglect | D · Potential harm Isolated | Corrected Sep 18, 2023 |
| Aug 25, 2023 | F-0690 | Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections. Quality of Life and Care Deficiencies · Clinical care | D · Potential harm Isolated | Corrected Sep 18, 2023 |
| Aug 25, 2023 | F-0692 | Provide enough food/fluids to maintain a resident's health. Quality of Life and Care Deficiencies · Clinical care | D · Potential harm Isolated | Corrected Sep 18, 2023 |
Reported from Payroll-Based Journal (PBJ) data, as published by CMS. Case-mix adjusted total: 2.82 (case-mix index 1.22).